Nordeston

Integrated Power Systems

PowerPlatform

Modular E-Houses and Skid-Mounted Electrical Power Systems.

PowerPlatform integrates Nord-Trans transformers, switchgear, Nord-Cell storage, and controls into pre-engineered power blocks for data center, utility, and industrial sites. Power conversion is supplied by a selected partner. Customers specify one integrated block, sized as a system.

Skid-Mounted Electrical Power Systems

PowerPlatform Skid

Nordeston PowerPlatform integrated electrical skid with transformer and electrical equipment enclosures on a common structural base.

An open or enclosed integrated electrical assembly, configured to customer requirements.

  • Nord-Trans MV/LV transformer (optional)
  • MV switchgear or ring main unit (optional)
  • LV main and distribution switchboard
  • Power conversion from a selected partner
  • Nord-Cell LFP battery storage
Configuration
Open or enclosed assembly, per customer requirements
Installation
Per customer requirements
Integration
Pre-assembled in the factory; test scope per model and project

Modular E-Houses & Integrated Electrical Modules

PowerPlatform Module

Interior of a Nordeston modular E-House with integrated electrical switchgear, distribution panels, cable trays, and HVAC systems.

A walk-in prefabricated electrical building that can house MV and LV switchgear, electrical distribution equipment, battery racks, HVAC, and fire protection, configured to project requirements.

  • Nord-Trans MV/LV transformer (optional)
  • Power conversion from a selected partner
  • Nord-Cell LFP battery racks
Configuration
Walk-in prefabricated electrical building
Installation
Outdoor or indoor, per project
Integration
Pre-assembled in the factory; test scope per model and project

Design specifications

Configuration

SkidOpen or enclosed assembly, per customer requirements

ModuleWalk-in prefabricated electrical building

Installation

SkidPer customer requirements

ModuleOutdoor or indoor, per project

Integration

SkidPre-assembled in the factory; test scope per model and project

ModulePre-assembled in the factory; test scope per model and project

MV/LV transformer

SkidOptional Nord-Trans dry-type cast resin

ModuleOptional Nord-Trans liquid-filled pad-mount

MV switchgear

SkidOptional ring main unit or MV switchgear

ModuleOptional ring main unit or MV switchgear

LV switchgear

SkidMain and distribution switchboard

ModuleMain and distribution switchboard

Power conversion

SkidPCS or UPS from a selected partner

ModulePCS or UPS from a selected partner

Battery

SkidNord-Cell LFP racks or 268 / 318 kWh cabinets

ModuleNord-Cell LFP racks inside the module

Cell chemistry

SkidLFP, prismatic cells

ModuleLFP, prismatic cells

Specifications are representative and subject to revision. Final values are confirmed at quotation stage. Ratings, thermal and fire protection configuration, communication protocols, test scope, and certifications are provided in model-specific technical documentation.

For standalone battery energy storage, see Nord-Cell.

Explore Nord-Cell

System Integration

One block, factory integrated.

Modular Nordeston PowerPlatform E-House undergoing factory assembly and electrical integration on a rail-mounted production platform.
  • One integrated block.

    Storage, power conversion, and medium-voltage equipment are specified and sized together, rather than procured from separate vendors.

  • Factory integration.

    Blocks are assembled in the factory. Factory integration is designed to support earlier energization, fewer hidden integration costs, less field rework, and more predictable O&M.

  • Standard blocks.

    Standard designs are sized around the selected PCS unit; the reference configuration uses one MV transformer per inverter. Approved designs can be reused across repeat orders and campus phases, and repeatable manufacturing supports phased deployment.

  • Clear scope.

    Storage, transformers, and controls are specified together under one scope of supply. Nordeston supplies the equipment, documentation, and technical support; EPC and interconnection filing remain with the owner's team, and every contract defines the division of scope.

  • Permitting and project documentation.

    Permitting documentation support, including fire safety documentation, can be included in project scope. Project documentation supports the owner's Section 48E ITC and domestic content analysis.

Engineered to project requirements

Support systems, including fire protection, thermal management, power and cable management, and monitoring and control, are configured per model and project and described in model-specific technical documentation. PowerPlatform can also be engineered around project-specific redundancy and availability requirements, subject to the selected system architecture.

Project support

PowerPlatform projects are supported by Nordeston project engineering, factory acceptance testing defined per model and project, commissioning support, long-term service agreements, and a critical spares inventory.

Specify PowerPlatform for your project.

Request detailed data sheets, configuration options, and project-specific pricing.